System 04

Fire-rated systems

Glazed partitions and doors with EI 15–EI 60 fire resistance — safety without giving up natural light.

  • Escape routes
  • Fire zone separations
  • Stairwells
  • Public buildings

Aluminium fire-rated systems provide integrity (E) and insulation (I) against fire for a set period. Used to separate fire zones, protect escape routes and divide adjoining units.

Fire resistance classes

EI 15, EI 30 and EI 60 — the number is the minutes of maintained integrity and insulation. Intumescent inserts in the profile chambers expand under heat, blocking the spread of fire and smoke.

Doors and screens

Single- and double-leaf doors with self-closers, fire-rated glazing (gel-filled laminated glass), top and side lights. Can integrate with access control and smoke venting.

Fire-rated system classes

Fire-rated system classes
ParametrEI 15EI 30EI 60
Resistance time15 min30 min60 min
Frame depth65 mm75 mm90 mm
Fire-rated glazingyesyesyes
Applicationpartitionsescape routesfire zones

System benefits

  • 01Regulatory compliance — fire tests and classifications
  • 02Transparency — large glazing despite fire-rating requirements
  • 03Visual consistency — the same profile lines as non-fire-rated systems
  • 04Integration — access control, smoke venting, self-closers

Contact

Let’s design this system for your building

Send us your drawings and sections — we’ll pick the variant, details and prepare a quote.